A pump is chosen by its duty point: the flow it delivers at a given head. Too small and the shower runs weak; too big and it cycles on and off and wastes power. Enter how high the pump must lift water, the pipe run, the flow you need and the pressure you want at the taps, and the calculator gives the total head and a rough motor size.

Pressure Pump Sizing Calculator

L/minAbout 10–12 L/min per outlet running at the same time; 25–35 L/min suits most houses.
mAbout 3 m per storey. Use a negative value if the outlets are lower than the pump.
m0 when the tank outlet is level with or above the pump.
m
bar2–3 bar gives a good shower. Most geysers are rated for 4–6 bar with a pressure control valve.

Your result

Pump duty point30 L/min at 32.2 m head

Flow
1.80 m³/h
Total head
32.2 m (3.16 bar)
Friction loss in the pipe and fittings
5.8 m
Water velocity in the pipe
1.56 m/s
Rough motor size
0.35 kW or larger

Choose a pump whose curve delivers this flow at this head near the middle of its range. Motor size assumes about 45% wire-to-water efficiency for small domestic pumps. Suction lift above 6–7 m needs a submersible or borehole pump.

Head, flow and the pump curve

Every pump has a curve: as the head it pumps against rises, the flow it delivers falls. Head is made up of three parts: the height the water must climb, the friction in pipes and fittings, and the pressure you want left at the outlet (1 bar is about 10.2 metres of head). The duty point from the calculator is what to look for on the manufacturer's curve. Ask suppliers to quote pumps that meet it, so you are comparing like with like.

Booster pumps, tanks and geysers

  • A pressure pump with a pressure vessel or electronic controller switches on when a tap opens and off when it closes; the vessel stops it cycling on small draws.
  • Pumping from a backup tank during outages needs a non-return valve and a changeover so the municipal supply and the pump do not fight each other.
  • Geysers are fitted with a pressure control valve, typically 400 or 600 kPa. Do not set a pump's cut-out above what the geyser and fittings are rated for.

Frequently asked questions

What size pressure pump do I need for my house?
Most single houses need about 25–40 L/min at 25–35 m of head, which is a 0.5–1 kW domestic booster. Double-storey homes, long runs or several bathrooms at once need more; use the calculator with your actual layout.
Can a pump boost low municipal pressure directly?
Many municipalities do not allow pumps to draw directly from the municipal supply, because they lower pressure for neighbours. The usual approach is to fill a tank from the main and pump from the tank. Check your municipal by-laws.

Get a free quote